Challenges in fueling hydrogen trucks in extreme cold

Canada鈥檚 Alberta Motor Transport Association has done research into operating hydrogen-diesel dual-fuel trucks and FCEVs in bitterly cold conditions. This story focuses on the fueling challenges it has uncovered.

The Alberta Motor Transport Association (AMTA) is a not-for-profit organization that represents over 75 percent of the more than 24,000 commercial transportation carriers across Alberta, Canada. While it supports education, training and member advocacy, it is also focused on research and innovation.

Image: alphaspirit via Adobe Stock

鈥淲e desire to accelerate technologies that enhance safety, extend operational efficiencies or support environmental stewardship for the commercial transportation industry,鈥 according to the AMTA website.

In a recent Mission Hydrogen webinar, AMTA reported on research into one such innovation: the long-distance use of hydrogen trucks in the province鈥檚 extreme cold weather conditions. This includes hydrogen-diesel dual-fuel vehicles as well as hydrogen fuel cell electric vehicles (FCEV).

According to webinar presenter Jamie King, who works in research and innovation for AMTA鈥檚 industry and advancement group and is AMTA鈥檚 subject matter expert regarding hydrogen trucks, the association has done trials with more than 20 carriers using Hydra Energy dual-fuel trucks, Hyzon FCEVs and Nikola FCEVs.

Regarding hydrogen-diesel dual-fuel technology in particular, King said one reason AMTA has focused on it is to help fleets with a relatively cost-effective transition to more sustainable on-highway solutions.

鈥淎 lot of fleets can鈥檛 afford to directly jump to fuel cell electric with the cost of investing in a brand-new vehicle,鈥 she said. 鈥淎nd what hydrogen diesel dual fuel allows you to do is take your current fleet to end-of-life. In Canada, for approximately $60,000 to $70,000, you can retrofit your current truck to be diesel dual-fuel.鈥

Want to see more insights from the power industry?

Cold-Weather Operation

In performing its trials, AMTA was particularly interested in understanding the challenges unique to operating these vehicles in Canadian environments.

鈥淥ne thing that鈥檚 become somewhat of a concern for us in Canada is a lot of the vehicles are produced in the U.S. and Europe,鈥 King said. 鈥淭he ones that are produced in the U.S. that we are getting 鈥 they typically are built for lighter loads, shorter distances and more mild temperatures.鈥

She added that as a result, AMTA looks to 鈥淎lberta-ize鈥 the trucks they get from the U.S. and abroad.

鈥淲e do really consider the colder temperatures more so than the hotter temperatures,鈥 King said. 鈥淥ur Nikola trucks came from Arizona, where they actually have to take into consideration the hotter temperatures. They鈥檙e looking at plus 40掳C (104掳F), whereas we鈥檙e looking at minus 40掳C (-40掳F).鈥

According to King, one unique temperature-related challenge is fueling hydrogen trucks. Part of the issue is due to the purity required for FCEVs.

Fuel Requirements

鈥淔uel cell-grade hydrogen needs to be 99.999999 percent pure,鈥 she said. 鈥淚f it isn鈥檛 that pure, it can actually compromise the integrity of the fuel cells in the truck. And usually, it means that there鈥檚 a higher water content if that purity is diluted.鈥

Hydrogen fueling nozzle type affects fuel access, refueling time

When fueling a hydrogen truck, the type of nozzle 鈥 high or low flow 鈥 is an important consideration.

鈥淢ost fuel cell electric trucks require a high flow, and many diesel dual-fuel trucks require low flow,鈥 said Jamie King, who works in research and innovation for the Alberta Motor Transport Association (AMTA). 鈥淗owever, switching out that nozzle in between fills isn鈥檛 practical. And it鈥檚 not a simple process 鈥 there is some time involved with it, and it鈥檚 a little bit laborious.鈥

As a result, many who operate hydrogen-diesel dual-fuel trucks are equipping them with an interchangeable nozzle to be able to refuel with high flow, King said.

鈥淭his allows them to fill in more locations and not be limited by the nozzle type,鈥 she said.

According to King, the other benefit of using a high-flow nozzle is that refueling takes less time.

鈥淎 fill with a low-flow nozzle can take upwards of an hour,鈥 she said, 鈥渁nd that鈥檚 something that drivers really need to take into consideration 鈥 the fact that they need to allot that time for filling and getting to the filling station.鈥

In many cases, operators using low-flow nozzles can schedule specific refueling times. This can, however, make trip planning more onerous.

鈥淪o, they really have to plan their routes pretty intricately to make sure that they allow time to get to the filling site, allow the time for filling, and then allow the time to get back to where they鈥檙e going.鈥

King said that purity 鈥 six nines 鈥 is not as critical for a dual-fuel truck.

AMTA works with Calgary, Alberta-based Suncor Energy to provide the hydrogen fuel necessary for the trucks in the trials, King said. Suncor provides AMTA with a 350 bar fuel-grade hydrogen filling station, allowing all the FCEVs to fuel there.

鈥淭he diesel dual-fuel trucks are also able to fuel there because they don鈥檛 need that same level of purity,鈥 King said.

In addition, King said AMTA introduced a new modular fueler in Nisku, Alberta, just outside of Edmonton. It is supplied by the Suncor production facility in Edmonton.

鈥淭his new fueler is able to provide fuel-cell grade hydrogen at 700 bar, which is a vast improvement over the 350 bar available at Suncor,鈥 she said.

King added that trucks requiring hydrogen at 700 bar that fuel at a 350-bar site can only fill halfway. 鈥淭hat can be quite limiting, with the distances that we鈥檙e looking at in Alberta.鈥

Low-Temperature Challenges

According to King, a temperature of -20掳C (-4掳F) is the point at which hydrogen trucks tend to either break down or underperform. For fueling specifically, she said such extreme low temperatures can compromise the operation of the gas transfer module (GTM).

鈥淥peration of the GTM in colder temperatures becomes somewhat temperamental, and if the trucks can鈥檛 fuel, obviously they can鈥檛 operate,鈥 King said. 鈥淭he GTM simply fails to operate in the extreme cold, which we have found becomes an issue if it is colder than -20掳C.鈥

Another issue is maintaining the six-nines purity required of hydrogen fuel cells.

鈥淭he other issue that comes into play when the temperature dips below -20掳C is the water content, as I mentioned, in the hydrogen,鈥 King said. 鈥淐ondensation instantly freezes, and then once it gathers in the lines and has a chance to warm up, even momentarily, the water dilutes the hydrogen purity, which means it鈥檚 no longer fuel cell-grade.鈥

When this happens, King said, there is no choice but to wait until the weather warms up enough.

鈥淲hen we get that less than fuel cell-grade-purity hydrogen, there鈥檚 not much we can do to really alleviate that issue until we can purge it all,鈥 she said.

According to King, many attempts have been made to mitigate this cold-weather issue. 鈥淏ut when it comes down to it, it鈥檚 just hard to insulate against that bitter cold.鈥

SwRI shows hydrogen-fueled Class 8 truck H2-ICE consortium developed truck on display at ACT Expo
An electric APU primer: supporting hotel loads in trucking without IC engines Dragonfly Energy, makers of the Battle Born Batteries brand of lithium-ion APUs, discussed the future of electric auxiliary power units (APU).
STAY CONNECTED

Receive the information you need when you need it through our world-leading magazines, newsletters and daily briefings.

CONNECT WITH THE TEAM
Andy Brown Editor, Editorial, UK - Wadhurst Tel: +44 (0) 1892 786224 E-mail: [email protected]
Neil Gerrard Senior Editor, Editorial, UK - Wadhurst Tel: +44 (0) 7355 092 771 E-mail: [email protected]
Catrin Jones Deputy Editor, Editorial, UK 鈥 Wadhurst Tel: +44 (0) 791 2298 133 E-mail: [email protected]
Eleanor Shefford Brand Manager Tel: +44 (0) 1892 786 236 E-mail: [email protected]
CONNECT WITH SOCIAL MEDIA